Compatible
Reusable SpO2 Finger Sensor |
-
High patient comfort;
-
Variant compatible with most popular original manufacturers
-
Excellent
value for money
-
Short
lead times/delivery times
|
Reusable
SpO2 Finger Sensor
|
|
|
|
|
|
|
Manufacturer |
Monitor
Type |
Original
Sensor |
Finger
Sensor
|
Baxter |
|
Biochem
(BCI) |
6100 |
BCI
3044 BCI 3444 |
|
3300,
3301, 3302, 3303, 3304, 3401, 9100 |
BCI
3044 BCI 3444 |
|
|
Bird |
|
Bruker |
|
Burdick |
|
Cormetrics |
118,
129 |
Nellcor
® DS100A |
|
118,
129, 120, 510, 556 |
Nellcor
® DS100A |
|
511 |
6051-0000-035 |
|
|
Criticare |
501,
503, 504, 507, 508, 581, 1100 Poet (602-3A), 1100-3 |
CSI
511-SD |
|
501,
503, 504, 507, 508, 581, 1100 Poet (602-3A), 1100-3 |
CSI
511-10L |
|
503
Spot |
511SD,
517SD |
|
|
Critikon |
8700
Serie, Dinamap Plus (alte Version) |
9084 |
|
970
Serie, Dinamap Plus (neue Generation) |
Nellcor
® DS100A |
|
8700
Serie, Dinamap Plus (alte Version) |
|
|
|
Datascope |
Passport,
Accustat |
0600-00-0026-01 |
|
Passport
(Factory Set for Nellcor ®) |
Nellcor
® DS100A |
|
Passport,
Accustat, 4 sat |
0600-00-0026-02
0020-00-0071-01 |
|
|
Datex |
CH-S,
CH-2S, CH-RS, Cardiocap II, M-Estpr, Oscar II, OSP-200,
Satlite, ULTSVI, ULTSVO, ULTSIO, ULTS00, AS/3, CG-2CS |
SAS-F |
|
CH-S,
CH-2S, CH-RS, Cardiocap II, M-Estpr, Oscar II, OSP-200,
Satlite, ULTSVI, ULTSVO, ULTSIO, ULTS00, AS/3, CG-2CS |
SAS-F4 |
|
|
|
|
|
|
|
Manufacturer |
Monitor
Type |
Original
Sensor |
Finger
Sensor
|
Dima
Italia |
|
Dräger |
Dräger
Oxipac 2000 |
BCI
3044 BCI 3444 |
|
Vitalert
1000,
Cicero |
Nellcor
® DS100A |
|
Narkomed |
Nellcor
® DS100A |
|
|
Eagle |
Eagle
3000, Eagle 4000, Dash, Solar, Tram Modular: 250SL, 450SL,
650SL, 850SL |
Nellcor
® DS100A |
|
|
Entri
Medical |
Propaq
102 104 106 |
Nellcor
® DS100A |
|
|
Fukuda
Denshi |
HG302
Module |
Nellcor
® DS100A |
|
|
Hellige |
Eagle
1000, 3000, SMU SMK, SMV |
Nellcor
® DS100A |
|
|
Hewlett
Packard |
Miracle
Adult System, Neonatal System, Merlin M1012A, M1024A,
78834C, 78352/4c |
Nellcor
® DS100A |
|
Miracle
Adult System, Neonatal System, Merlin M1020A, M1024A,
78834C, 78352/4C |
Nellcor
® DS100A + M1900B |
|
Miracle
Adult System, Neonatal System, Merlin M1020A, M1024A,
78834C, 78352/4C |
M1190A |
|
|
Invicare |
|
Ivy
Biomedical |
405A,
405D |
Nellcor
® DS100A |
|
405P,
405T |
Nellcor
® DS100A |
|
|
Kontron |
|
|
|
|
|
|
Manufacturer |
Monitor
Type |
Original
Sensor |
Finger
Sensor
|
Lynn
Medical |
|
M.
D. E. |
Escort
100 OP11A, Escort 300A |
Nellcor
® DS100A |
|
Escort
II OPT30 |
Nellcor
® DS100A |
|
|
Mennen |
Horizon
XL (Ohmeda) |
800-060-540,
800-060-630 |
|
Horizon
XL (Nellcor) Mercury, Mercury 1200, MR 1300 |
Nellcor
® DS100A |
|
|
Nellcor* |
N180,
N6000, N190, N20 |
Nellcor
® DS100A |
|
N100,
N200 |
Nellcor
® DS100A |
|
N3000 |
Nellcor
® DS100A |
|
|
Nihon
Kohden |
Nihon
Kohden |
Th
101-S |
|
Nihon
Kohden |
|
|
|
Nonin |
8500
Serie, 8600 Serie |
8000AA-1 |
|
|
Novametrix |
510,
511 |
8744,
8793 |
|
505,
515, 520, 7000, Oxypleth |
8776,
8791 |
|
500 |
8660 |
|
505,
510, 515, 520, 7000, Oxypleth |
|
|
|
Ohmeda |
370,
3740, 3800, 4700, 5250RGM, Rascal II |
6051-0000-035 |
|
370,
3740, 3800, 4700, 5250RGM, Rascal II |
6051-0000-035 |
|
|
Pacetec |
|
Protocol
Systems |
Propaq
206-EL, 204-EL, 202-EL, 106EL |
Nellcor
® DS100A |
|
|
|
|
|
|
|
Manufacturer |
Monitor
Type |
Original
Sensor |
Finger
Sensor
|
Siemens |
All
types System |
Nellcor
® DS100A |
|
|
Simed |
|
Spacelabs |
90651A-07,
90419-01, 90489, 90466, 90467, 90465, 90351-D/G |
015-0130-00 |
|
90419,
90501, 90651A-03 |
369083-001 |
|
90651A-08,
90489, 90466, 90467, 90465, 90351-D/G |
(0150-0150-00
175-0706-00) |
|
|
Return