Vital Sign Monitors

Pulse Oximeter

ECG

Veterinary Thermometers

 

Mediaid Sensors

Compatible Sensors

Infusion Pump

Features:

  • Compact vital signs monitoring system for checking Oxygen Saturation (SpO2), Pulse Rate (BPM), Non-Invasive Blood Pressure (NIBP), and Temperature
  • Bright, high resolution LCD screen to display the Pleth Waveform as well as the SpO2 and Pulse Rate readings
  • Printer facility for printing reports immediately
  • Accurate Blood Pressure reading in less than 40 seconds
  • Six different language options for easy access to clinicians across the world
  • Separate bright LED displays for systolic, diastolic and mean Blood Pressure readings
 
Display

High resolution fluorescent backlit 240 x 64 LCD graphical screen
for Pleth waveform, SpO2, and BPM readings

Three 3-digit, bright 7-segment LED displays for Systolic, Diastolic and mean Blood Pressure readings

 
Pulse Oximetry and Heart Rate

Range

(% SpO2)     1 - 100%
(Pulse)        25 - 300 BPM

Resolution (% SpO2)     1%
(Pulse)         1 BPM

Reading Accuracy

(% SpO2)     (100 - 70%) ± 2%
                    (≤ 69%), Unspecified
(Pulse)         (25 - 300 BPM), ± 2 BPM
 
Electrical Ratings

AC Voltage AC 100 - 230 V, 50/60 Hz
Battery Type Recharageable internal battery
Battery Run Time Up to 45 minutes on a full-charge with SpO2, and NIBP readings
once every 10 minutes.
 

 

 
Non-Invasive Blood Pressure

Technique Oscillometric
Measurement Range

Systolic    40 - 265 mmHg
Diastolic   20 - 200 mmHg
Mean       27 - 222 mmHg
Pulse       25 - 300 BPM

Initial Inflation Pressure Large Animal:   160 mmHg (default) & Variable from 120 – 280 mmHg
Small Animal:   160 mmHg (default) & Variable from 60 – 280 mmHg
Systolic Accuracy Mean Error less than ± 5 mmHg
SD less than ±8 mmHg

Diastolic Accuracy

Mean Error less than ± 5 mmHg
SD less than ±8 mmHg
 
Temperature Readings

Scale Selectable °F/°C
Accuracy ±0.3 °F / ±0.2 °C
Patient Temp Range 73.4 °F - 113 °F / 23 - 45 °C
Measurement Time Dependent on probe placement & patient condition;
normally within 60 seconds.
 
Environmental Conditions

(Acceptable conditions for operating, storage and transport)

Atmospheric Pressure 770 - 282.45 mmHg
1026 - 377 hPa
Humidity 5 - 95% (non-condensing)
Operating Temperature 0 - 40 °C

Storage / Transport
Temperature

-30 - 65 °C
 